Operating Voltage | 10V – 30V (DC), 9V – 20V (AC) |
---|---|
Operating Current | 10mAmps (standby), 200mAmps (operating) |
Operating Temperature | 0°C – 75°C |
Telephone Line Voltage | 24V – 50V DC |
Telephone Line Current | 20mAmp – 90mAmp |
Dialling Method | Tone (DTMF) 16-Digit Dialling Capability |
Speaker Volume | 8Ω Programmable – 1 Watt (max) 80dB Level at 1 Metre – 425 Hz |
Trigger Button | 2 X Dry Contacts – Optically isolated |
Microphone | 2K Impedance, Operating Range 5 Metres |
Relay Contact Rating | 2A/30V (DC) |
Recorded Voice Message | 16 Seconds, Locally & Remotely Programmable |
SD Card (Optional) | Auto Programming & Logging of Recorded Calls |
Self Diagnostic Lift Car Message Alerts | Phone Line Failure – Every 5 Minutes, Power Supply Fault – Every 15 Minutes |
EM-1 Powered Emergency Lift Telephone
Powered Emergency Lift Telephone
An emergency telephone is one of the most crucial pieces of safety equipment utilized in an elevator. For this reason, we have developed a reliable, easy-to-use, fully-featured, self-contained product designed and perfected to facilitate communication between a person in need of assistance and the service provider.

Dimensions | 118.5 × 81.5 × 54 cm |
---|---|
Operating Voltage | 18 – 24V DC |
Inputs | Dry Contact, Ac ve Low (ON) |
Output | Open Collector, 24V, 50mA (max) |
StationBus | 4-wire, 400m (max), 8 Sta on Total |
Status Indication | Status (RGB LED) |
Battery Type | 12V SLA 0.8Ah |
Battery Runtime | 4 Hours (Standby) |
Operating Temperature | 0 – 50°C |
Operating Humidity | 90% max rela ve humidity, noncondensing |
Mounting | DIN Rail |
EM-181 Emergency Lift Telephone System
Emergency Lift Telephone System
An emergency telephone is one of the most vital pieces of safety equipment used in an elevator. We have developed a reliable and easy to use product meeting all EU Lift Standards of EN-81, designed to maintain communication between a person in need of assistance and a service provider.

Telephone Line Voltage | 24V DC – 50V DC |
---|---|
Operating Current | 25mA (standby), 90mA (operating) |
Operating Temperature | 0°C – 75°C |
Relay Voltage | 9V—24V 1A—No/Nc Selectable |
Speaker Volume | Programmable—80dB @ 1 meter 425Hz |
Trigger Button | Dry Contacts—optically isolated |
Digital Voice Message | 16 seconds programmable message |
EM-2 Telephone Line Powered Emergency Telephone
Telephone Line Powered Emergency Telephone
An emergency telephone is one of the most crucial pieces of safety equipment. For this reason, we have developed a reliable, easy-to-use, fully-featured, self-contained product designed and perfected to facilitate communication between a person in need of assistance and the service provider.

Telephone Line Voltage | 24V DC – 50V DC |
---|---|
Loop Current | 20mA – 90mA |
Dialling Method | Tone (DTMF) 75ms ON – 75ms OFF |
Dimensions | 75mm x 70mm x 220mm |
EM-32HP Emergency Telephone Handset
Emergency Telephone Handset
Analog Line-Powered Handset designed for use as an emergency telephone. The user can pick up the handset and manually dial the required number, or pair it with a pixel gateway for automatic calling of a pre-programmed telephone number when the handset is picked up.

Operating Temperature | 0°C – 75°C |
---|---|
Dialling Method | Tone (DTMF) 16-Digit Dialling Capability |
Speaker Volume | Programmable 80dB @ 1 meter 425Hz |
Trigger Button | Dry Contacts – optically isolated |
Recorded Voice Message | 16 seconds, Locally & Remotely Programmable |
Help Points Internal and External Help Points
Internal and External Help Points
Introducing the emFONE range – the ultimate solution for hands-free emergency calls in any environment. Whether it’s indoor or outdoor applications, we’ve got you covered with our rugged and aesthetically pleasing design, available in the emFONE EM-1 or EM-2 models.

Operating Voltage | 12 – 24V DC |
---|---|
Operating Current | 50mA (Idle), 75mA (Active) |
Configuration | On-Device HTTP Webserver |
Ethernet | 10BASE-T |
Protocol | Pixel VoIP with DTMF over IP |
StationBus | 4-wire, Up to 400m (max), 8 Station(max) |
Status Indication | Status (RGB LED) |
Voice ID Message | 16 seconds (max) |
Inputs | Opto-isolated, 24V DC(max) |
Output | Relay (N/O), 30V, 1A (max) |
Operating Temperature | 0 – 50°C |
Operating Humidity | 90% max relave humidity, noncondensing |
Mounting | DIN Rail or Wall Mount |
LX1 Digital IP Communication System
Digital IP Communication System
The LX1 digital lift emergency phone communications solution provides high-quality hands-free loud speaking intercom and emergency autodialling to the system console or external world and complies with the latest EN81-28 lift standards. With ethernet integration into managed building networks, 2-wire connectivity for easy upgrades, remote management and monitoring of all devices, this system offers flexible and redundant alarm call routing options. Additionally, the battery backup system ensures that your lifts are always covered.