Telephone Line Voltage | 24V DC – 50V DC |
---|---|
Operating Current | 25mA (standby), 90mA (operating) |
Operating Temperature | 0°C – 75°C |
Relay Voltage | 9V—24V 1A—No/Nc Selectable |
Speaker Volume | Programmable—80dB @ 1 meter 425Hz |
Trigger Button | Dry Contacts—optically isolated |
Digital Voice Message | 16 seconds programmable message |
EM-2 Telephone Line Powered Emergency Telephone
Telephone Line Powered Emergency Telephone
An emergency telephone is one of the most crucial pieces of safety equipment. For this reason, we have developed a reliable, easy-to-use, fully-featured, self-contained product designed and perfected to facilitate communication between a person in need of assistance and the service provider.
Operating Voltage | 12 – 24V DC |
---|---|
Operating Current | 50mA (Idle), 75mA (Active) |
Configuration | On-Device HTTP Webserver |
Ethernet | 10BASE-T |
Protocol | Pixel VoIP with DTMF over IP |
StationBus | 4-wire, Up to 400m (max), 8 Station(max) |
Status Indication | Status (RGB LED) |
Voice ID Message | 16 seconds (max) |
Inputs | Opto-isolated, 24V DC(max) |
Output | Relay (N/O), 30V, 1A (max) |
Operating Temperature | 0 – 50°C |
Operating Humidity | 90% max relave humidity, noncondensing |
Mounting | DIN Rail or Wall Mount |
LX1 Digital IP Communication System
Digital IP Communication System
The LX1 digital lift emergency phone communications solution provides high-quality hands-free loud speaking intercom and emergency autodialling to the system console or external world and complies with the latest EN81-28 lift standards. With ethernet integration into managed building networks, 2-wire connectivity for easy upgrades, remote management and monitoring of all devices, this system offers flexible and redundant alarm call routing options. Additionally, the battery backup system ensures that your lifts are always covered.