The CT-E10/RSL and CT-E10/SPI interface module converts OTIS RSL serial link and KONE SPI serial link to the Pixel Technologies DataBus protocol.
Downloads
Features
- OTIS RSL interface.
- Kone SPI interface.
- Pixel Technologies DataBus output protocol
- Ethernet connectivity
- Supports up to 127 floor levels
Details
| Operating Voltage | 12 – 24V DC (absolute maximum 33V DC) |
|---|---|
| Operating Current | 65mA, 100mA with Wi-Fi Active |
| Input Protocols | GAL CAN, OTIS RSL |
| Output Interface | RS-485 |
| Output Protocols | Pixel Technologies Mode 3 |
| Pixel DataBus Length | Up to 64 nodes & 400m (max) |
| Wi-Fi Access point | 802.11b/g/n |
| Configuration | On-Device HTTP Webserver |
| Status Indication | Status (RGB LED) |
| Operating Temperature | 0 – 50°C |
| Operating Humidity | 90% max relative humidity, noncondensing |
| Mounting | Surface mounting or DIN Rail |